No subsystem on a spacecraft works without electricity: not the computer, not the reaction wheels, not the heaters that stop the hydrazine from freezing, not the transmitter that links it to Earth. The Electrical Power System (EPS) has to generate energy from a primary source, store it for when that source is missing, regulate it and distribute it with protection, all for fifteen years, under radiation and with no possibility of maintenance. In this lesson you will see how a space solar cell works, how the arrays and batteries of a satellite in low Earth orbit and in geostationary orbit are sized, when a radioisotope thermoelectric generator (RTG) is chosen and which trade-offs shape the design. The EPS typically accounts for of the order of 20-30 % of a satellite's dry mass, so getting it wrong is expensive.
Architecture of a power subsystem
An EPS has four blocks:
- Primary source: solar arrays (almost all satellites), radioisotope generators (probes to the outer solar system, Mars rovers), fuel cells (Apollo, the Space Shuttle) or primary batteries (missions lasting hours or days, such as probes descending into an atmosphere).
- Energy storage: rechargeable batteries, today almost always lithium-ion, for eclipses, peak loads and launch.
- Conditioning and regulation: the power control and distribution unit (PCDU) sets the bus voltage, manages battery charging and dissipates or disconnects excess array power.
- Distribution and protection: harness, switches, current limiters and fuses that isolate a fault before it brings down the bus.
The first architectural decision is the bus voltage. A higher voltage reduces the current and, with it, the copper mass and the I²R losses. Small satellites use 28 V (inherited from aviation); high-power geostationary platforms, 50 V or 100 V; the Space Station generates at 160 V DC and distributes at 124 V. Above about 100-150 V, sustained arcing between array cells in the low-orbit plasma becomes a problem, which calls for special insulation designs.
The second is whether the bus is regulated (fixed voltage in sunlight and in eclipse) or unregulated (the voltage follows that of the battery). A regulated bus simplifies the units and is the norm in Europe and on large platforms; an unregulated one saves converters and is common on small satellites.
The space solar cell
A photovoltaic cell is a p-n junction: photons with energy above the semiconductor's bandgap create electron-hole pairs that the junction's field separates. A single material wastes energy in two ways: photons with less energy than the bandgap are not absorbed, and the excess energy of the more energetic ones is lost as heat. That is why today's space cells are triple-junction: three stacked sub-cells (GaInP / GaInAs / Ge), each absorbing one band of the spectrum.
| Technology | Typical on-orbit efficiency (AM0, beginning of life) | Power temperature coefficient | Use |
|---|---|---|---|
| Monocrystalline silicon | ~14-17 % | of the order of −0.4 to −0.5 %/K | Older satellites, ISS (original arrays), low-cost constellations |
| Single-junction gallium arsenide | ~18-20 % | of the order of −0.2 to −0.3 %/K | Little used today |
| Triple-junction GaInP/GaInAs/Ge | ~28-30 % | of the order of −0.2 to −0.3 %/K | Standard in GEO, science and most satellites |
| Thin-film or flexible cells | lower per unit area, much higher per kilogram | variable | Roll-out arrays (the ISS iROSA), constellations |
The reference spectrum in space is AM0 (air mass zero), with a mean irradiance at 1 AU of S = 1,361 W/m² (TSI). The power per unit area of a cell is:
P₀ = η · S ideal power per m² of cell, normal to the Sun
P_BOL = P₀ · I_d · cos θ beginning of life (BOL)
P_EOL = P_BOL · L_d end of life (EOL)
L_d = (1 − d)^t cumulative degradation over t years at rate d per year
η: cell efficiency; with η = 0.30, P₀ ≈ 408 W/m².I_d: inherent degradation, which lumps together the array packing factor (not everything is cell), diode and harness losses, cell mismatch, shadowing and operating temperature. Wertz and Larson give a nominal value of 0.77, with a range of 0.49 to 0.88.θ: angle between the array normal and the Sun. A steerable array keeps it close to 0°; a body-mounted array loses a lot.d: annual degradation, mainly from radiation damage (covered in the space environment). As an order of magnitude, in low Earth orbit 3.75 %/year for silicon and 2.75 %/year for gallium arsenide (Wertz and Larson design values); in GEO the degradation depends mainly on the accumulated solar proton fluence.
Temperature matters: an array in sunlight operates at 50-80 °C and every kelvin takes away of the order of 0.2-0.5 % of power depending on the technology. Coming out of eclipse, on the other hand, the array is very cold (it can be below −80 °C) and delivers more than its nominal voltage for a few minutes.

How much light and how much shadow: eclipse geometry
In a circular orbit the satellite is in shadow when the Earth comes between it and the Sun. With a cylindrical shadow model and the Sun in the orbit plane (beta angle β = 0, the worst case), the shadow half-angle is ρ = arcsin(R_E / r), and the eclipse fraction is 2ρ / 360°.
| Orbit | Period | Maximum eclipse | Eclipses per year |
|---|---|---|---|
| LEO, 400 km (ISS) | ~92.6 min | ~36 min | ~5,700 |
| LEO, 500 km | 94.6 min | 35.8 min | ~5,500 |
| Dawn-dusk Sun-synchronous LEO | ~100 min | almost never, except for a short season | few |
| GEO, 35,786 km | 23 h 56 min | ~69-72 min | ~90, in two seasons of about 45 days around the equinoxes |
In GEO the cylindrical model gives about 69 minutes; counting the penumbra, the practical maximum is of the order of 70-72 minutes. What matters for design: in low Earth orbit the battery goes through of the order of 5,500 cycles a year; in GEO, about 90. That completely changes how it is sized.
Solar array sizing
On the daylight side the array must deliver the load power and also replace the energy consumed during eclipse, paying for the losses along the energy paths. Wertz and Larson's formula:
P_sa = ( P_e · T_e / X_e + P_d · T_d / X_d ) / T_d
P_e, P_d load power in eclipse and in daylight
T_e, T_d duration of eclipse and daylight
X_e, X_d efficiency of the path array → battery → load (eclipse) and array → load (daylight)
with direct energy transfer (DET): X_e ≈ 0.65 and X_d ≈ 0.85
with peak power tracking (MPPT): X_e ≈ 0.60 and X_d ≈ 0.80
Array mass is estimated from its specific power: of the order of 40-100 W/kg for rigid triple-junction wings, and considerably more for flexible roll-out wings. The Station's new iROSA arrays, which unroll like a carpet, deliver of the order of 20 kW each.
Batteries: capacity, depth of discharge and cycle life
The energy the battery must deliver in the worst eclipse is E = P_e · T_e. But it cannot be emptied completely: a battery's cycle life falls very sharply with depth of discharge (DoD). The required nameplate capacity is:
C = P_e · T_e / (DoD · η_dis · N) in Wh, with N independent batteries in service
| Chemistry | Specific energy (cell level) | Historical use | Typical design DoD in LEO / GEO |
|---|---|---|---|
| Ni-Cd | ~30-40 Wh/kg | 1960-1990 | ~15-25 % / ~50 % |
| Ni-H₂ | ~50-60 Wh/kg | GEO and Hubble, ISS until 2017-2021 | ~30-40 % / ~70-80 % |
| Lithium-ion | ~150-250 Wh/kg | Current standard | ~20-30 % / ~60-80 % |
Lithium-ion replaced Ni-H₂ because it offers about three times more energy per kilogram and has no memory effect; in exchange, it requires strict per-cell voltage control (overcharging it is dangerous), a narrow temperature range (from about 0 to 30 °C in service, ideally kept around 10-20 °C) and protection against thermal runaway. The Station replaced its 48 Ni-H₂ batteries with 24 lithium-ion ones over several spacewalks between 2017 and 2021: half the units for the same function.
Regulation: direct energy transfer or peak power tracking
The current-voltage curve of an array has a maximum power point (MPP) that moves with temperature and illumination. There are two philosophies:
- Direct energy transfer (DET): the array is connected to the bus through shunt regulators that divert the excess. The most widespread is the S3R regulator (Sequential Switching Shunt Regulator), which short-circuits array sections one by one. It is simple, efficient and robust, but does not exploit the excess voltage of a cold array.
- MPPT: a series DC-DC converter makes the array operate at its MPP. It gains up to 10-20 % in energy in the conditions furthest from nominal (cold array coming out of eclipse, missions with large variations in distance from the Sun), but the converter always loses a small percentage and adds mass and complexity.
Rule of thumb: DET for long-life, high-power missions with stable conditions (GEO); MPPT for low orbits with many eclipses, small satellites and interplanetary probes.
Far from the Sun: when arrays are no longer enough
The solar flux falls with the square of the distance: S(r) = 1,361 · (1 AU / r)² W/m².
| Destination | Distance from the Sun | Flux relative to 1 AU |
|---|---|---|
| Venus | 0.72 AU | 1.91 |
| Mars | 1.52 AU | 0.43 |
| Asteroid belt (Ceres) | 2.77 AU | 0.13 |
| Jupiter | 5.2 AU | 0.037 |
| Saturn | 9.5 AU | 0.011 |
In addition, under low light and intense cold (LILT conditions, low intensity low temperature) cells perform differently from what ground tests indicate. Juno showed that solar power is still possible at Jupiter: three wings with about 60 m² and some 18,700 cells, which give of the order of 500 W at Jupiter and would give of the order of 14 kW at 1 AU. Beyond Jupiter, or on the surface of a planet with long nights and dust, the usual answer is nuclear. At the other extreme, close to the Sun, the problem is the opposite: Parker Solar Probe partially retracts its arrays and cools them with pressurised water.
Radioisotope thermoelectric generators (RTGs) and other sources
An RTG converts the decay heat of plutonium-238 into electricity by means of thermocouples (Seebeck effect), with no moving parts. Pu-238 is ideal: an alpha emitter (little shielding needed), with a half-life of 87.7 years and a thermal power of about 0.57 W per gram of isotope. The fuel is in the form of ceramic plutonium dioxide, clad in iridium and in graphite blocks designed to survive a launch vehicle explosion or a re-entry.
Power decays for two reasons: the decay of the isotope, P(t) = P₀ · 2^(−t / 87.7), of the order of 0.8 % a year, and the ageing of the thermocouples, which in total leaves a drop in electrical power of a few per cent a year.
| Generator | Missions | Electrical power at start | Mass | Efficiency |
|---|---|---|---|---|
| MHW-RTG | Voyager 1 and 2 (3 per spacecraft) | ~158 W each, ~470 W per spacecraft | ~38 kg | ~6.6 % |
| GPHS-RTG | Galileo, Ulysses, Cassini, New Horizons | ~290-300 W | ~56 kg | ~6-7 % |
| MMRTG | Curiosity, Perseverance, Dragonfly | ~110 W | ~45 kg | ~6 % |
The Voyagers are the extreme example: launched in 1977 with about 470 W each, they lose of the order of 4 W a year, and NASA has spent years switching off heaters and instruments one by one so that the spacecraft keep working within what their RTGs provide. Their link with Earth, with a transmitter of about 20 W, is analysed in the link equation.
The future alternative is Stirling radioisotope generators, with efficiencies of the order of 25-30 %, that is, four times less plutonium for the same power, at the cost of moving parts. And for powers of tens of kilowatts (lunar bases, nuclear electric propulsion) fission reactors are being developed; NASA's Kilopower/KRUSTY test demonstrated in 2018 a fission reactor on the ground with Stirling conversion.

Fuel cells and other sources
Hydrogen-oxygen fuel cells deliver kilowatts of power for days or weeks with high efficiency (of the order of 60-70 %), and their by-product is drinking water. That is why they were used on Gemini, Apollo and the Space Shuttle, whose three fuel cells delivered of the order of 7 kW each continuously. They are no use for missions lasting years because the fuel runs out; they reappear in studies of regenerative storage for the 14-day lunar night, where a battery would be too heavy.
| Source | Typical power | Duration | System specific power | When it is chosen |
|---|---|---|---|---|
| Primary batteries | W to kW | hours to days | high for short missions | Atmospheric probes, descent modules |
| Fuel cells | 1-10 kW | days to weeks | medium | Short-duration crewed spacecraft |
| Solar array + battery | W to ~100 kW | years | of the order of 10-30 W/kg at system level | Almost everything out to Jupiter |
| RTG | 100-300 W | decades | ~2.5-5 W/kg | Outer solar system, dusty surfaces or long nights |
| Fission reactor | 10 kW to MW | years | under development | Bases, nuclear electric propulsion |
The power budget and operating modes
The central EPS document is the power budget: a table with the consumption of each unit in each operating mode (launch, Sun acquisition, safe mode, nominal, transmission, manoeuvre, eclipse) and its duty cycle. P_d and P_e for sizing come from it. The payload usually takes the largest share; heaters weigh much more in eclipse and in safe mode than the nominal mode suggests.
A margin is placed on top of the budget, larger the less mature the design (of the order of 20-30 % in a Phase A study, decreasing as units are measured), and the energy balance per orbit is checked: the battery must end each orbit with the same charge it started with, in the worst case and at end of life. Systems engineering explains how these margins are managed throughout the project.
Design trade-offs
- Large array and small battery, or the other way round. In LEO, recharging in a short time dominates; in GEO the battery dominates because of the eclipse duration, but the few cycles allow it to be discharged deeply.
- Fixed or steerable array. Fixed is cheaper, lighter and has no mechanism; steerable gives 30-60 % more energy per unit area and a more stable unit temperature, but adds a mechanism with slip rings that is critical for reliability.
- High or low voltage. Higher voltage saves copper, but complicates insulation, arcing and unit compatibility.
- Interaction with the rest of the spacecraft. A large wing adds inertia, flexibility and drag in low orbit; its temperature depends on thermal control; its degradation, on the radiation environment. No EPS decision is made in isolation.
Key points
- The EPS generates, stores, regulates and distributes; it is usually of the order of 20-30 % of the dry mass.
- Triple-junction cells: ~30 % efficiency, ~408 W/m² ideal at 1 AU; with inherent and radiation degradation, of the order of 250 W/m² at end of life.
- In LEO the array must deliver more than twice the daytime load, and the battery goes through ~5,500 cycles a year (DoD 20-30 %); in GEO, ~90 eclipses a year of up to ~72 min (DoD 60-80 %).
- Solar flux falls as 1/r²; beyond Jupiter, or on dusty surfaces with long nights, Pu-238 RTGs are used (87.7 years, ~0.57 W/g, ~6 % efficiency).
- The power budget by mode and the energy balance per orbit, with margins, are at the heart of the design.
Further reading
- J. R. Wertz, W. J. Larson (eds.), Space Mission Analysis and Design, 3rd ed., Microcosm/Kluwer (1999), ch. 11.4 (power subsystem).
- P. Fortescue, G. Swinerd, J. Stark (eds.), Spacecraft Systems Engineering, 4th ed., Wiley (2011), chapter on electrical power systems.
- M. R. Patel, Spacecraft Power Systems, CRC Press (2005).
- NASA, Radioisotope Power Systems: Multi-Mission Radioisotope Thermoelectric Generator (MMRTG), fact sheet, NASA Glenn Research Center.
- ECSS-E-ST-20C, Space engineering: Electrical and electronic, ESA-ESTEC (latest revision).
Test yourself
Why must the solar array of a satellite in low Earth orbit deliver considerably more power than the load consumes on the daylight side?
What is the half-life of the plutonium-238 that powers RTGs?
A probe goes from 1 AU to 5.2 AU from the Sun (Jupiter). What fraction of the solar power remains, ignoring other effects?
Why is the depth of discharge of a lithium-ion battery limited to 20-30 % in low Earth orbit?
What is the main advantage of a maximum power point tracker (MPPT) over direct energy transfer (DET)?